Ge Marquette Mac 8 Ekg 12 Lead Ecg Interpretive Manual



  1. Ge Marquette Mac 8 Ekg 12 Lead Ecg Interpretive Manual 6th Edition
  2. Ge Marquette Mac 8 Ekg 12 Lead Ecg Interpretive Manual Download
  3. Ekg Interpretation
  4. Ekg 12 Lead Placement
  5. Ekg 12 Lead Interpretation
  6. Ge Marquette Mac 8 Ekg 12 Lead Ecg Interpretive Manual Pdf
  • The MAC 5500 interpretive electrocardiograph with 12- or 15-lead analysis, full-sized paper format, alphanumeric keypad and standard monochrome waveform display. Marquette 12SL ECG analysis program for adult and pediatric interpretation. Options include data transmission, remote query, Hi-Res, PHi-Res, and color display.
  • 1-2 MAC™ 800 Resting ECG Analysis System 2031504-182F Introduction Manual Information Purpose This manual describes the safe and ef fective operation of the MAC™ 800 Resting ECG Analysis System. Intended Audience This manual is written for clinical professionals who use, maintain, and/ or troubleshoot the MAC™ 800 Resting ECG Analysis System.

Ge Marquette Mac 8 Ekg 12 Lead Ecg Interpretive Manual 6th Edition

Hii will thankful if some one can send me the user manual frensh of mac 5000 Reply-BMC1 8 months ago: 8 months ago 2 page printout i have a GE MAC 5000 EKG machine. It works fine but at completion it always print TWO (2) pages. The first page has the 12 leads plus 3 chosen rhythm leads. The Marquette MAC 500 Deluxe EKG - Same as MAC 500 Plus, with interpretation software built-in. Utilizes Marquette's exclusive 12SL ECG analysis program. Marquette MAC 1200 The Marquette MAC 1200 CardioSmart EKG - 12 lead EKG with a full sized 8.5 x 11 inch paper format and alphanumeric keyboard.

Now from
£2,034.00 inc VAT
  • 1 year integration with EMIS, TPP SystmOne and Vision included - Saves time and increases patient safety
  • 1 year MediServe Support cover included - Includes unlimited technical support, repair and servicing with loan equipment
  • GE Marquette 12SL – High quality interpretation used in the majority of UK hospitals
  • Hook Up Advisor – Allows you to resolve quality issues prior to acquisition
  • 5 year manufacturer's warranty

Trade-in package available – contact us for more information

Also available to rent - Find out more

See how i3 Integration works

Our diagnostic solutions are designed to save you time and improve patient safety. This product is available with the following options:

I3 Integration

I3 integration will automatically retrieve a patient's details from EMIS, TPP SystmOne or Vision and file a PDF report and associated coded results upon test completion to their medical record.

Find out more about I3 integration

Mediserve Support

This product is available with our unique MediServe support package, which includes unlimited technical support and a full aftercare service.

Find out more about Mediserve support

Installation & Training

Our dedicated team can install and train you on this product at a time that is convenient for you.

EcgFind out more about install & training

The MAC 600 ECG Machine from GE Healthcare is a high performance, portable and compact 12 lead resting ECG machine. MAC 600 ECG is ideal for a busy GP surgery wanting to perform ECG’s where a PC may not be readily available and community nurses requiring a portable ECG device for domiciliary visits. It is supplied with a market leading 5 year warranty.

Using the included Intelligent Integration Interface (I3) software*, the MAC 600 ECG machine is fully integrated with all the leading NHS clinical systems from EMIS, TPP and Vision. The software automatically files a high quality ECG report (as a PDF) and a coded result to the patient's record on test completion.

The MAC 600 System utilises ‘Hook Up Advisor’, which combined with the Marquette® 12SL ECG analysis programme, gives the most accurate automated interpretation in existence. The ECG can be monitored on the large colour screen and ‘Hook Up Advisor’ indicates the quality of the ECG signal from every lead to ensure acquisition of a high quality ECG. ECG’s can be printed out immediately using the integral printer or stored in the memory for batch printing.

If the use of unencrypted SD cards is not permitted at your practice then you will need to use the MAC 600 with the CardioSoft PDF Software at an additional cost. Please contact our sales team if you require any further information.

What’s inside the package?

  • MAC 600 ECG System
  • 100 Ambu SUPAtab ECG electrodes
  • 10 Ambu crocodile clips
  • Protective hard carry case

*ongoing license cost applies

The manual attachment of diagnostic reports to a patient’s medical record is a time consuming process and, combined with the inputting of codes, can often mean you spend more time carrying out administration tasks than caring for your patients. Manual data entry can also compromise patient safety, through the attachment of test results to the incorrect patient medical record.

I3 integration provides a solution to these problems by acting as a link between your GP clinical system and a range of 12 lead ECG, ABPM and spirometry devices.

I3 will retrieve a patient’s details from the EMIS, TPP SystmOne or Vision clinical systems and automatically pass this information to the diagnostic device you want to use, ready to perform your test. Once all the tests have been completed, I3 will then file a PDF report of the test results and any associated coded results directly into the patient’s medical record automatically. This makes your diagnostic testing safer, faster and easier.

Ge Marquette Mac 8 Ekg 12 Lead Ecg Interpretive Manual Download

ECG interpretation: Marquette® 12SL™ ECG Analysis Program for Adults and Pediatrics

Computerised measurements: 12-lead analysis

ECG analysis frequency: 500 samples/second

Digital sampling rate: 2,000 samples/second/channel

ECG on-screen preview: On-screen preview of acquired 10-second ECG waveform

Dynamic range: AC Differential ± 5mV, DC offset ±300 mV

Resolution: 4.88 μV/LSB @ 500 sps

Frequency response: –3 dB @ 0.01 to 150 Hz

Low cut-off frequency: 0.01 Hz, 0.02 Hz, 0.16 Hz or 0.32 Hz (-3 dB limits)

High cut-off frequency: Configurable at 20 Hz, 40 Hz, 100 Hz or 150 Hz

Adaptive AC filter: 47 Hz to 53 Hz when set to 50Hz, 57 Hz to 63 Hz when set to 60 Hz

Common mode rejection: >100 dB (with AC filter switched on)

Input impedance: >10MΩ @ 10 Hz, defibrillator protected

Patient leakage: <10 μA

Heart rate meter: 30 to 300 BPM ±10% or ±5 BPM

Start-up time: Less than 7 seconds

Patient Information

Ekg 12 lead interpretation

Supported patient information: Patient ID, secondary ID, age, date of birth, gender.

Alphanumeric entry: T9 type for patient ID and secondary ID.

Display

Display type: 4.3 inch (110 mm) diagonal, TFT LCD with LED graphics backlit (colour optional)

Display resolution: 480 X 272 pixels with scrolling waveform

Display data: Heart rate, patient ID, clock, battery power indicator, waveforms, lead labels, speed, gain and filter settings, warning messages, information messages, prompts, 12-leads standard.

Writer

Writer technology: Thermal dot array

Writer speed: 5, 12.5, 25, & 50 mm/s

Number of traces: 3 leads + 1 rhythm or 3 leads; user selectable

Writer sensitivity/gain: 2.5, 5, 10, 20, 10/5 mm/mV

Writer speed accuracy: ±5%

Writer amplitude accuracy: ±5%

Writer resolution: Horizontal 40 dots/mm @ 25 mm/s, 8 dots/mm vertical

Paper type: Thermal. Z-fold perforated, 80 mm width, 280 sheets/pack. Roll paper 15.7 m.

Keyboard

Type: Type Membrane keyboard with tactile feedback

Software Standard

Resting ECG mode: Records and prints 12-lead resting ECGs with 10-second duration as standard

Hookup Advisor™: Provides visual indication of signal quality

Multi-language support: Supports 16 languages

Software Options

Colour: Colour display

External storage: 200 ECGs in external memory (SD card)

Transmission: ECG data transmission via serial cable

XML format: ECG storage in XML format

PDF format: 1 ECG storage in PDF format

Communication (optional)

MUSE® Cardiology Information System Compatible

Serial cable: ECG transmission to MUSE Cardiology Information System

Serial cable: ECG transmission in XML format

SD card interface: Compatible with MUSE v7 CardioSoft™ Interface

SD card interface: Compatible with Cardiosoft V6.51

Ekg Interpretation

Electrical

Power supply: External AC/DC adaptor or battery operation

External Adaptor Specifications

Input voltage: 100 to 240 VAC ±10%

Input current: Maximum 0.6A @ 90 VAC, 0.3A @ 240 VAC

Input frequency: 50 to 60 Hz ± 3Hz

Output voltage: 12V ± 5%

Battery Specifications

Battery type: Replaceable and rechargeable, Lithium Ion

Battery capacity: 7.2V typical, 2.25 AH ±10%

Ekg 12 Lead Placement

360 minutes of continuous operation without recording or 250 ECGs in 2.5 X 4 format at 25 mm/S and 10 mm/mV or 100 minutes continuous rhythm print at 25 mm/S and 10 mm/mV.

Battery charge time: Approximately 3 hours from total discharge (with display off)

Physical Specification

Height: 81 mm

Width: 263 mm

Depth: 208 mm

Weight: 1.2 Kg including battery, without paper

Environmental Specification

Temperature

Operating: 5°C to 40°C

Transport/storage: -15°C to 50°C

Humidity

Operating: 25% to 95% RH non-condensing

Transport/storage: 25% to 95% RH non-condensing

MediServe

Ekg 12 Lead Interpretation

Lead

Ge Marquette Mac 8 Ekg 12 Lead Ecg Interpretive Manual Pdf

Keeping your equipment running smoothly is critical to the success of your practice. Numed Healthcare offer a complete product support package called MediServe. More about MediServe